SMS-301 Redundancy Switch

Operation

Rev. 3

3-21

3.5.1.7 Stored

Faults/Alarms

Refer to Figure 3-10.

OPERATIONAL X

(Status Only)

X = 0 through 9.

Displays the fault status of the currently selected on-line modulator and
demodulator.

When a stored fault is present, the date and time of the fault will be displayed
alternately.
(Status Only)

Note: Date and time of faults also are displayed.

Press [

←] or [→] to display faults within the 1:1 switch, such as the following:

COMMON

Battery Clock - Battery or clock fault.

+12V Supply - +12V supply fault.

+5V Supply - +5V supply fault

Power Supply #1 - Power supply #1 fault.

Power Supply #2 - Power supply #2 fault.

Controller - Controller power ON/OFF cycle fault.

Modem COMM Link - Modem communications fault.

Modem Verify- Prime and backup modems do not match.

DEMOD Verify - Prime and backup DEMODS do not match.

Interface Module - Interface module is missing or will not program

fault.

CLEAR??
STORED FAULTS

Allows the operator to clear all stored faults within the memory of the 1:1 switch.

Press [ENTER], then ‘YES’ is displayed. Press [ENTER] to confirm clearing all
stored faults, or press [CLEAR] to exit without clearing stored faults.