beautypg.com

Comtech EF Data SMS-301 User Manual

Page 21

background image

SMS-301 Redundancy Switch

Introduction

Rev. 3

1–7

Table 1-3. 1:1 Switch Specifications (Continued)

Parameters
Controlled/Monitored

Operation mode:

Automatic or manual

Switching mode:

Independent or dependent mod/demod

Modulator on-line delay
Demodulator on-line delay
Modem on-line:

A or B (dependent mode)

Modulator on-line: A or B (independent mode)
Demodulator on-line: A or B (independent mode)
Remote configuration (local only): EIA-232 or EIA-485, address, baud,

parity, bits per word

Remote mode (Switch)
Clear stored faults
Current faults
Stored faults
Switch status
Firmware
Time/date
Equipment type
Store/recall multiple switch configurations
Remote access to modulator/demodulator status
Modem configuration copy to opposite modem

Configuration Retention

Will maintain configuration for at least one year without prime power

Switch to Modem
Communications

Interface type:

EIA-485 (2-wire)

Connector:

9-pin D-sub

Protocol:

Addressable (see remote control protocol, Appendix A)

Prime Power

85 to 264 VAC, 47 to 63 Hz, 30W (redundant inputs)
(Optional) 42 to 56 VDC, 40W (redundant inputs)

Size

19 W x 15.2 D x 1.75 H inches (1 RU)
(48.3 x 39 x 4.4 cm)

Weight

< 9 lbs (4 kg)

Operating Temperature

0

° to 50° C (32° to 122° F)

Humidity

< 95%, non-condensing

EMI

CE Mark Certification