DMD2050E Universal Satellite Modem

AUPC Operation

MN-DMD2050E Revision 2

G–4

When the rain diminishes, Local modem will see the remote Es/No begin to increase. Local
modem will lower its power level. The operation is therefore a feedback control loop with the
added complication of a significant time delay.

The AUPC Menu Functions and their descriptions are shown in Table G-1 and Table G-2.

Table G-1. Local AUPC Functions

Function

AUPC Available Options

Description

AUPC MODE

DISABLE, NEARSIDE,
RADYNE, EFDATA

Enables/Disables the AUPC to function locally

NOMINAL POWER

0 TO -25 dB

Sets default output power to be used

MINIMUM POWER

0 TO -25 dB

Sets minimum output power to be used

MAXIMIM POWER

0 TO -25 dB

Sets maximum output power to be

TARGET Eb/No

4.0 TO 16 dB

Desired E

b

/N

0

of remote modem

TARGET Es/No

0.0 TO 25 dB

EBEM MODE ONLY: Desired E

s

/N

0

of remote

modem

RANGE Es/No

0.0 TO 2.0 dB

EBEM MODE ONLY: Dead range of desired E

s

/N

0

where no action is taken

TRACKING RATE

6.0 to 0.5 dB/MIN

Adjustable in .5dB increments

LOCAL CL ACTION

HOLD, MAXIMUM, NOMINAL

Allows user to determine what power setting the
remote modem will use in the event of a carrier loss
at the local side.

REMOTE CL ACTION

HOLD, MAXIMUM, NOMINAL

This setting allows users to determine what local
output power setting to use in the event that the
remote end has a carrier loss.

1. The AUPC Menus are located under the Modulator Menu as shown in Section 4.
2. The EF AUPC Menu displays when EFAUPC Framing is enabled in the Demod and Mod set up menus.
3. Highlighted areas are activated when modem is set to EF AUPC

Table G-2. Remote AUPC Functions (EF AUPC Only)

Function

AUPC Available Options

Description

AUPC MODE

Disable, EFDATA

Enables/Disables the AUPC to function remotely

LOOPBACK

Enabled/Disabled

Loop back test over satellite link

TX 2047 TEST BER

Enabled/Disabled

Initiates 2047 Test pattern BER Test

RX 2047 BER

Status Menu

Identifies the BER status on the distant RX side

AUPC DEF LVL

Sets default output power to be used

The Remote AUPC Menus are only supported by EFAUPC