5 ext clk (j16), 1 ibs network alarms configuration, 2 closed net alarms configuration – Comtech EF Data DMD-2050E User Manual

Page 159: 3 rts carrier alarms configuration

background image

DMD2050E Universal Satellite Modem

External Connections

MN-DMD2050E Revision 2

5–7

5.3.4.1

IBS Network Alarms Configuration

IBS Prompt Alarms

IBS Service Alarms

Pins 7 through 9

Pins 10 through 12

Includes
TX Minor Alarms or
TX Minor Alarm and TX Major Alarms

Includes
RX Minor Alarms or
RX Minor Alarms and RX Major Alarms

5.3.4.2

Closed Net Alarms Configuration

When the unit is configured for a Closed Net operation, the contact closures for Prompt and
Service alarms are used for a summary of either:

All major and minor alarms

All minor alarms

Use the General menu, Baseband Relays to configure this operation.

5.3.4.3

RTS Carrier Alarms Configuration

RTS Carrier Alarms
Pins 10 through 12

Service alarms can be configured for the RTS Carrier Alarms.

The Baseband Relay can be set to

monitor the RTS Carrier. When the RTS Carrier is used and the Baseband Relay is configured
for RTS Keyline, the Service alarms pins 10 through 12 are used for monitoring the RTS signal.
See Radyne App Note 230 for more information.

5.3.5 EXT CLK (J16)

Label

Description

Connector Type

Input Levels

EXT CLK J16 External Clock Port

75 Ohm Female BNC

70/140 MHz IF

0.3 to 5 Vpp

(Sine or Square wave)

This manual is related to the following products: