3.19.4 Actual Overhead Rate Calculation

The following is the actual calculation the modem does to calculate the overhead ratio:

1. The modem calculates the minimum in-band rate to limit the size of the user data slots to

2,500 bits (the result is truncated to an integer).

Minimum In-Band = (User Data Rate * Control Ratio)/((Control Ratio + 1) * 250)

2. Using the bigger of Minimum In-Band or the selected In-Band, the modem calculates the

number of bits for each user data slot (result is truncated to an integer).

Slot Bits = (User Data Rate * (Control Ratio * 10))/(In-band Rate * (Control Ratio + 1))

The actual ratio the modem uses is:

Actual Ratio = (Slot Bits + 10)/Slot Bits

Example 1:

User Data Rate: 1,024,000 bps

In-Band Rate: 19,200 bps

Control Ratio: 1 to 7

Minimum In-Band = (1,024,000 * 7)/((7 + 1) * 250) = 3,584

(less than In-Band Rate)

Slot Bits = (1,024,000 * (7 * 10))/(19,200 * (7 + 1)) = 466

Actual Ratio = (466 + 10)/466 = 1.021

Example 2:

User Data Rate: 6,312,000 bps

In-Band Rate: 19,200 bps

Control Ratio: 1 to 7

Minimum In-Band = (6,312,000 * 7)/((7 + 1) * 250) = 22,092 (

more than In-Band Rate)

Slot Bits = (6,312,000 * (7 * 10))/(22,092 * (7 + 1)) = 2,500

Actual Ratio = (2,500+ 10)/2,500= 1.004