Comtech EF Data DMD-2050E User Manual
Page 101

DMD2050E Universal Satellite Modem
Theory of Operation
MN-DMD2050E Revision 2
3–59
rate through the modem. The overhead channel is recovered at the far end. This added channel
is termed variously “An Overhead Channel”, ”Service Channel”, “Async Channel” or in IESS
terminology an “ES to ES Data Channel.” The basic frame structure used by the multiplexer is
that specified in the IESS-309 Standard, resulting in a 16/15 Aggregate t0 through-Data Ratio.
For Regular Async:
(Standard IBS), the Baud Rate is approximately 1/2000 of the
Data Rate listed in Table 3-5.
For Enhanced Async:
(IBS Async.), the Baud Rate is selectable, but Data Rate is
limited.
The maximum Baud Rate is 19,200 bps for IBS Async. Two software-controlled modes are
designed into the card to best utilize the available bits; “Standard IBS” and “IBS (Async)”. The
characteristics of the Channel Interface is also determined by the standard or Async mode.
The Async Channel can be set under software-control to either RS-232 or RS-485 mode. The pin
assignments for both modes are shown in Table 3-5. The “RS-485” Setting controls the output
into tri-state when the modem is not transmitting data, allowing multiple modem outputs to be
connected together.
Table 3-5. Baud Rate Examples
Kbps
Standard IBS
Baud Rate Example
Kbps
Enhanced Mode
Baud Rate Example
128
64
9.6
300
256
128
19.2
600
384
192
32
600
512
256
64
1200
640
320
128
2400
768
384
192
4800
896
448
256
4800
1024
512
320
9600
1152
576
384
9600
1280
640
448
9600
1408
704
512
9600
1536
768
576
9600
1664
832
640
19200
1792
896
704
19200
1920
960
768
19200
1920
960
768
19200
2048
1024
832
19200