DMD2050E Universal Satellite Modem

Theory of Operation

MN-DMD2050E Revision 2

3–59

rate through the modem. The overhead channel is recovered at the far end. This added channel
is termed variously “An Overhead Channel”, ”Service Channel”, “Async Channel” or in IESS
terminology an “ES to ES Data Channel.” The basic frame structure used by the multiplexer is
that specified in the IESS-309 Standard, resulting in a 16/15 Aggregate t0 through-Data Ratio.

For Regular Async:

(Standard IBS), the Baud Rate is approximately 1/2000 of the
Data Rate listed in Table 3-5.

For Enhanced Async:

(IBS Async.), the Baud Rate is selectable, but Data Rate is
limited.

The maximum Baud Rate is 19,200 bps for IBS Async. Two software-controlled modes are
designed into the card to best utilize the available bits; “Standard IBS” and “IBS (Async)”. The
characteristics of the Channel Interface is also determined by the standard or Async mode.

The Async Channel can be set under software-control to either RS-232 or RS-485 mode. The pin
assignments for both modes are shown in Table 3-5. The “RS-485” Setting controls the output
into tri-state when the modem is not transmitting data, allowing multiple modem outputs to be
connected together.

Table 3-5. Baud Rate Examples

Kbps

Standard IBS

Baud Rate Example

Kbps

Enhanced Mode

Baud Rate Example

128

64

9.6

300

256

128

19.2

600

384

192

32

600

512

256

64

1200

640

320

128

2400

768

384

192

4800

896

448

256

4800

1024

512

320

9600

1152

576

384

9600

1280

640

448

9600

1408

704

512

9600

1536

768

576

9600

1664

832

640

19200

1792

896

704

19200

1920

960

768

19200

1920

960

768

19200

2048

1024

832

19200