3 alarms, 1 major transmit alarms, 2 major rx alarms – Comtech EF Data DMD-2050E User Manual

Page 165: 3 alarms 6.3.1 major transmit alarms

background image

DMD2050E Univeral Satellite Modem

Maintenance and Troubleshooting

MN-DMD2050E Revision 2

6–3

6.3 Alarms

6.3.1 Major Transmit Alarms

Alarm

Description

Status

FPGA CFG

A transmit FPGA hardware failure exists.

{Pass/Fail,
Unmasked/Masked}

DSP CFG

A transmit FPGA failure exists.

{Pass/Fail,
Unmasked/Masked}

SCT Clock PLL

The Tx SCT Clock PLL is not locked. This alarm flashes on
during certain parameter changes. If the alarm is on constantly,
there is a configuration problem within the modem.

{Pass/Fail,
Unmasked/Masked}

SYM Clock PLL

The Tx Symbol Clock PLL is not locked. This alarm flashes on
during certain parameter changes. If the alarm is on constantly,
there is a configuration problem with the incoming clock to the
modem (SCTE).

{Pass/Fail,
Unmasked/Masked}

LB Synth PLL

The Tx L-Band Synthesizer is not locked. This alarm flashes on
during certain parameter changes. If the alarm is on constantly,
there is a configuration problem within the modem.

{Pass/Fail,
Unmasked/Masked}

IF Synth PLL

The Tx IF Synthesizer is not locked. This alarm flashes on
during certain parameter changes. If the alarm is on constantly,
there is a configuration problem within the modem.

{Pass/Fail,
Unmasked/Masked}

Forced Alarm

Allows the user to disable or enable forcing of the Tx summary
alarm.

{DISABLED,
ENABLED}

Ethernet WAN

The WAN Port is not operating.

{Pass/Fail,
Unmasked/Masked}

TRANSEC NOT RDY

This alarm is acgtive during the time that the TRANSEC card is
booting

{Pass/Fail,
Unmasked/Masked}

6.3.2 Major Rx Alarms

Alarm

Description

Status

FPGA CFG

A receive FPGA hardware failure exists.

{Pass/Fail,
Unmasked/Masked}

DSP CFG

A receive DSP failure exists.

{Pass/Fail,
Unmasked/Masked}

SIGNAL LOCK

The demod cannot lock to a signal.

{Pass/Fail,
Unmasked/Masked}