California Instruments
You can run “Test Panels…”
between the A/D card and the
Highlight NI PCI-6250: “Dev1”,
continuous, set Input Configuration
Make sure the PACS is powered
PACS. Of course, the power
measurement system.
Set the power source to 230 Volt
differential input amplifier and
Volt rms for a 230 Volt – 50 Hz
MX-CTSL
Revision J
to do a further functional check of the CTS hardware,
the PACS (CTS signal conditioning unit).
“Dev1”, select “Test Panels…”, set Channel Name to “Dev1/ai0”, set Mode to
Configuration to RSE, set Rate(Hz) to 10000.
powered up, and the A/D card cable is properly attached
source needs to be operating, and must supply an
Volt – 50 Hz. This voltage is routed to logical channel
differential input amplifier and a 100: 1 attenuation factor in the PACS. The display should be about 2.30
Hz input voltage. (See below picture for detail)
CTSL Compliance Test System
53
hardware, and interconnect cable
set Channel Name to “Dev1/ai0”, set Mode to
attached to both the card, and the
an appropriate voltage to the
channel 0 of the A/D card, via a
attenuation factor in the PACS. The display should be about 2.30