AMETEK MX CTSL User Manual
Page 136

User Manual
MX-CTSL Compliance Test System
15.3
PACS-3-75 General Specifications
The PACS-3-75 unit creates the mechanical and electrical interface between the AC source, the
EUT and the PC. It provides the necessary isolation and signal conditioning to perform the
measurements needed.
PACS Model:
PACS-3-75
Number of phases
3
Channels
Voltage and Current
6
Connector Style
Front panel
none
Rear panel
terminal block
Maximum Voltage
L- L
540 Vac
L – N
312 Vac
Maximum Current
Front panel
75A rms/phase
Input Voltage
Rear panel IEC320
115V / 230V Nominal
±
10%
Input Frequency
50 / 60Hz
Input Current
less than 0.6A (115v)
less than 0.3A (230v)
Dimensions
HxWxD (inch)
3.5 x 16.8 x 22
HxWxD (mm).
89 x 427 x 560
Weight
Lbs / kg.
12 / 5.4
Voltage Range: The input voltage range is 0 to 312V rms L-N.
The 1-phase or 3-phase voltage is applied to input terminal block TB4.
Current Range: The max. input current is 75 A rms.
Frequency may not be 50Hz depending on power source used and application.
California Instruments
Revision H
133