30
3.4.2
Front Panel Controls
The front panel contains the AC power On/Off switch, the BYPASS or ENGAGE status lights and a manual
MODE switch button. The mode switch button is normally enabled and the OMNI-3-37MX state is
controlled through the use of this button. The “ON “ LED indicates the OMNI-3-37MX module is powered
up.
The front panel power switch is located on the left hand side of the OMNI-3-37MX cabinet front. There is a
built in delay for engaging or disengaging the contactors when turning the OMNI-3-37MX on and off.
If the OMNI-3-75MX is part of a MXCTSHL system, it will be mounted in the OMNI-3-75 cabinet. In that
case, two circuit breakers will be present. (See illustration above). These are used to connect either OMNI
to the PACS-3-75 input. Close only one breaker at a time. Refer to user manual P/N 7003-972 on
MXCTSHL configuration details.
OMNI-3-75
Connect
Breaker.
OMNI On/Off
Switch
OMNI-3-37MX
Connect
Breaker.
OMNI-3-75
Manual Mode
Control.