Chapter 8: Maintenance
The fuse assembly can be removed by squeezing the two tabs toward each other, and pulling it
away from the docking station. The fuses are p/n 04563-000. See the following figure.
Figure 8-10. Docking Station Fuse
Docking Station Internal Fuse
Symptoms: When the docking station is switched on, the blue power light does not come on,
but the docking station can charge a battery manually.
WARNING: Unplug power from the docking station before starting.
The docking station cover is NOT interlocked. Remove the power cord at
the charger.
1. Remove the ten screws from the back cover of the docking station.
Two of these are on the sides, near the bottom.
Figure 8-11. Docking Station Rear Cover Screws (8 of 10)