Chapter 5: Connectivity
CAN Bus B
Connector type
DB9F
Use
CAN Bus
Pin No.
Designation
Notes
1, 4, 8
No Connection
2
CANL_B
CAN Communication differential pair
3, 6
GND
Direct GND
5
SHIELD GND
Bead filter to GND
7
CANH_B
CAN Communication differential pair
9
CANB_12V_OUT_SW 12 V @ 0.5 A Max (switched in SW)
Digital I/O
Connector type
HDB44F
Designation
Pin No.
Hardware
Software
Notes
1
INPUT_1.1
Input_1.1
0 – 30 V Range, R
in
= ~3.9 kΩ
2
INPUT_1.2
Input_1.2
0 – 30 V Range, R
in
= ~3.9 kΩ
3
INPUT_1.3
Input_1.3
0 – 30 V Range, R
in
= ~3.9 kΩ
4
INPUT_1.4
Input_1.4
0 – 30 V Range, R
in
= ~3.9 kΩ
5
BANK1
Common for INPUT_1.X
6
INPUT_2.1
Input_2.1
0 – 30 V Range, R
in
= ~3.9 kΩ
7
INPUT_2.2
Input_2.2
0 – 30 V Range, R
in
= ~3.9 kΩ
8
INPUT_2.3
Input_2.3
0 – 30 V Range, R
in
= ~3.9 kΩ
9
INUIT2.4
Input_2.4
0 – 30 V Range, R
in
= ~3.9 kΩ
10
BANK2
Common for INPUT_2.X
11
INPUT_3.1
Input_3.1
0 – 30 V Range, R
in
= ~3.9 kΩ
12
INPUT_3.2
Input_3.2
0 – 30 V Range, R
in
= ~3.9 kΩ
13
INPUT_3.3
Input_3.3
0 – 30 V Range, R
in
= ~3.9 kΩ
14
INPUT_3.4
Input_3.4
0 – 30 V Range, R
in
= ~3.9 kΩ
15
BANK3
Common for INPUT_3.X