Poe dynamic – Xtramus APMPT-4 V2.4 User Manual
Page 99
99
E-mail: [email protected]
Website: www. Xtramus.com
XTRAMUS TECHNOLOGIES
®
5.4.7. POE Dynamic
A. Setup
Port: Select the port to perform dynamic loading function.
Loading No.: The order of loading.
Enable: Enable the loading to perform its function.
Load (Watt): The loading power in watts.
Time (sec): The time duration for loading.
Prepare Load (Watt): The initial loading power before the test.
Prepare Load Time (ms): The initial loading time before the test.
Class: The loading range in watts where Class 0 is 0.44 to 12.95, Class 1 is 0.44 to 3.84, Class 2
is 3.84 to 6.49, Class 3 is 6.49 to 12.95 and Class 4 reserved for PSE.
Delay time: The time delay between two Loading.
Total Loading Time: The total time for running all Loading.
Enable Line Emulation/Emulation Length (M): Emulate the test on the set cable length in meter.
Cable Select: Select the type of cable of the test.