beautypg.com

Lineemulate – Xtramus APMPT-4 V2.4 User Manual

Page 129

background image


129

E-mail: [email protected]

Website: www. Xtramus.com

XTRAMUS TECHNOLOGIES

®

5.7.7. LineEmulate

This task allows you to set the LES-5160 device or other line emulation equipment which connects to

DUT ports. The function is active until the next 'LineEmulate' task. LineEmulate must be executed prior

to the task which needs the line emulation function and it's of no meaning when tested alone.

Refresh: click this button and the APMPT-4 begins to detect the LES-5160 devices on the network.

The list of the detected LES-5160 devices will be added on the margin below.

Description

A.

This filed shows the IP address of the LES-5160 device.

B.

Enable to set wire length: check this function, then you can set the wire length

emulated by each XLE-C5E module installed in the LES-5160 chassis.

C.

You can set the wire length emulated by each XLE-C5E module installed in the

LES-5160 chassis, respectively.

There are three optional wire lengths: