beautypg.com

Xtramus APMPT-4 V2.4 User Manual

Page 107

background image


107

E-mail: [email protected]

Website: www. Xtramus.com

XTRAMUS TECHNOLOGIES

®

with the DUT via network. The IP and route settings of the NIC should be correctly configured to

ensure the normal network communications with the Telnet Server.

Via NuStream Port:

Under this mode, the module installed in NuStreams-600i chassis will

connect with the DUT via network. The IP and route settings of the port should be correctly

configured to ensure the normal network communications with the Telnet Server. You can choose

the port that will be connected with the DUT through Port Select. And you can set the Port IP,

Port Netmask, Gateway to communicate with the DUT.

Script Setup: To execute scripts for serial port tests, you can choose to Run Script File, or Run

Script.

Run Script File: Click Load File to load a text file (*.txt) on your PC.

Run Script: You can edit/input a script with console commands in the field down below. Click <

Add Waiting to add a waiting command to the edit area. You can set the amount of seconds for

the waiting command in the field down below. To clear all texts in the edit area, click Clear.

Wait after Setup: You can set the waiting time for the system to halt after finishing configuring.

Add Hotkey: You can indicate a command as hotkey for script between Ctrl+A to Ctrl+Z.

Clear: clear the contents you input in the text box.

Enable Terminal Log:

You can choose whether to print the contents transmitted by the COM or

Telnet into the executing log by tests.

Third party Client: You can check this function to make the third party software as the visual

interaction window. APMPT4 will function as an transfer station (virtual Telnet server), which will

feedback the communication details between COM or Telnet and DUT to the third party software

interfaces via Telnet protocols , receive the manual input commands by the third party users via

Telnet and forward the commands to the DUT via Telnet or COM.

Wait Client Disconnected: When checking this function, the user can interact with the DUT after

executing the scripts by manually inputting commands before closing the window and exiting the

task. Or the task will be exited directly after executing the scripts.

Keyword setup:

This table shows information regarding to the scripts.

Key Word Case Sensitive: Decide whether the script is case sensitive.
Halt on if Fail: Decide whether to ignore other tasks and exit the task when error happens.

Enable Wildcard (‘?‟,‟*‟): Decide whether to support wildcard.

Misc