slot-time before starting to transmit packets again if this function is enabled.
Reset SFP Module (Fiber Only): Selecting this function will allow system to turn Off SFP port and
then turn On the SFP port.
Enable S/N Error Check: Selecting this option will enable the capturing of S/N Error.
Insert Elongated Frame Gap: This function is only for XM-RM-8XX modules.When enabling this
function, 1 bit-time of frame gap will be inserted after a certain amount of packets are sent and
decrease packet loss.
Halt on if fail: If you enable this function, system will stop if the test fails.
Up Packet Setting:
Transmit by Time: The 1 to Many-UC test will be performed for the set amount of time here.
Transmit by Packet: The 1 to Many-UC test will be performed for the set amount of packet here.
Tx Pkt Timeout: This field will be available for setting when you select the Transmit by Packet
function. If the time spent for transmitting packet exceeds the Tx Pkt Timeout you set here, the
test will stop and the result will be fail.
Down Packet Setting:
Transmit by Time: The 1 to Many-UC test will be performed for the set amount of time here.
Transmit by Packet: The 1 to Many-UC test will be performed for the set amount of packet here.
Tx Pkt Timeout: This field will be available for setting when you select the Transmit by Packet
function. If the time spent for transmitting packet exceeds the Tx Pkt Timeout you set here, the
test will stop and the result will be fail.
Stream Counter Report: Click the check box so the APMPT-4 will save the 1 to Many-UC test result
in Microsoft Excel format.
Dynamic Random Seed: For random packets, selecting this option will generate variable packets,
disabling this function will not generate variable packets.
T/L (0x): You can set the T/L (0X) after MAC address in this field.
Auto Check X- TAG Offset: X-TAG is a 12-byte tag which is developed by Xtramus and embedded
at 45th~56th bytes of each testing frames generated by Rapid-Matrix for multi-stream tests. X-TAG
will be added to all the testing frames generated by NuApps-MultiUnits-RM.
Traffic Direction Mode: You can scroll down and choose the direction of the traffic on this field.
Tx Payload: You can set the content of the transmitting packets with the Payload scroll-down menu.
MAC Setup:
Clicking the MAC Setup option will pop up a window to modify each module
card‟s port MAC Address.