5.7.2. Media Pre-Setting

Test MDIX by Media Pre-setting mode or force MDI (straight-through connection) or MDIX (crossover

connection) mode of DUT.

Setup

Type Select: Click the scroll-down menu to choose the link mode for Media Pre-Setting test. Three

modes are available: Auto MDI-X, Force MDI, and Force MDIX. Please note that since XM-RM600

series module cards do not support Force MDI-X, all XM-RM6XX modules will be tested under Force

MDI-II mode instead.

Waiting Time: APMPT-4 will halt at least for the Waiting Time you input here during test process.

Halt on if Fail: If you enable this function, system will stop if the test fails.

Port Select: By clicking this button, a Select Ports for Testing window will pop up, allowing you to

select the module cards and the ports you would like to use for the task.