Xtramus APMPT-4 V2.4 User Manual
Page 57
57
E-mail: [email protected]
Website: www. Xtramus.com
XTRAMUS TECHNOLOGIES
®
Media Select: Click the scroll-down menu to choose if all the connecting cables are Copper or
Fiber.
Minimum Waiting Time: APMPT-4 will halt at least for the Minimum Waiting Time you input here
during auto-negotiation process.
Media Type Waiting Timeout: If the time spent for auto-negotiation exceeds the Media Type
Waiting Timeout you set here, the test will stop and the test result will be fail.
Link up sequentially: APMPT-4 makes connections to ports sequentially (one-by-one). Therefore,
DUT‟s Link LEDs will be ON in a one-by-one manner as well. If any problems happen during the test,
it will be suspended immediately. Users can identify which port is causing the problem by checking
DUT‟s port LEDs.
Link Status Check: APMPT-4 will check all ports in this task are connected properly before test.
Reset SFP Module (Fiber Only): Selecting this function will allow system to turn Off SFP port and
then turn On the SFP port.
LED Check Setting: This window can remind the
user how DUT LEDs‟ display should be during the
task. The information you set here will be displayed
in the Checking LED Display window which pops up
right after you click the Start button on the main
window, shown as the picture down below. You can
also specify the standing time of the Checking LED
Display window by checking Enable waiting time and inputting its value. During the standing time
of Checking LED Display window, you can decide and manually operate whether the LED Check
test is
“Pass” or “Fail” by correspondingly clicking the buttons. If you don‟t check the Enable waiting
time, the Checking LED Display window will stand permanently until you manually make an
operation.