beautypg.com

Xtramus APMPT-4 V2.4 User Manual

Page 9

background image


9

E-mail: [email protected]

Website: www. Xtramus.com

XTRAMUS TECHNOLOGIES

®

D. Filter Test

This filter test should filter all packets with the same source MAC address and destination MAC Address.

For the test packets transmitted are all with the same source MAC address and destination MAC

address and the DUT should filter this kind of packet.

Perform filter test on DUT in layer2 with different speeds,

modes

and various configurations. The

following tasks transmit frames with same DA (destination address) and SA (source address).

PT2-FT-10H, (10Mbps, Half Duplex)

PT2-FT-10F, (10Mbps, Full Duplex)

PT2-FT-100H, (100Mbps, Half Duplex)

PT2-FT-100F, (100Mbps, Full Duplex)

PT2-FT-1G, (1Gbps, Full Duplex)

PT2-FT-10G, (10Gbps, Full Duplex)

PT2-FT_GROUPS (Perform Layer 2 Filter Test by two groups with different media types such as

100Mbps and 1Gbps for DUT ports with different maximum speeds.)

E. CRC Error Test
CRC Checksum is registered at the end of Ethernet frame.

Perform CRC (Cyclic Redundancy Check) error test on DUT in layer2 with different speeds,

modes

and

various configurations for the last 4 bytes of CRC to be filtered. For normal DUT, frame with error CRC

should be filtered. The following tasks transmit frames with CRC errors

.

PT2-CRC-10H, (10Mbps, Half Duplex)

PT2-CRC-10F, (10Mbps, Full Duplex)

PT2-CRC-100H, (100Mbps, Half Duplex)

PT2-CRC-100F, (100Mbps, Full Duplex)

PT2-CRC-1G, (1Gbps, Full Duplex)

PT2-CRC-10G, (10Gbps, Full Duplex)

PT2-CRC-GROUPS (Perform Layer 2 CRC check test by two groups with different media types

such as 100Mbps and 1Gbps for DUT ports with different maximum speeds.)