Xtramus APMPT-4 V2.4 User Manual
Page 100
100
E-mail: [email protected]
Website: www. Xtramus.com
XTRAMUS TECHNOLOGIES
®
Alternative: A network cable contains 4 twisted pair (8 totally) copper wire. The Alternative
function can lead input power from DUT to different pairs for the requirement of test allows you to
choose which pins provide the power. You can choose Mode A (Powered via Pin 1, 2, 3, and 6), or
Mode B (Powered via Pin 4, 5, 7, and 8). For more information regarding to network cable lines and
how they are related to RJ-45 jack, please refer to the Alternative explanation in 5.4.1 POE
Connect.
Halt on if Fail: The test will halt if the test fails.
Wait for Check Result: System will wait for the set amount of time before checking the test result.
Port Select: By clicking this button, a Select Ports for Testing window will pop up, allowing you to
select the module cards and the ports you would like to use for the task.
B. Help
You can see the system status of your task on this field.