Echelon Mini FX User Manual
Page 66

Mini FX User's Guide
53
• If you do not have a standard manufacturer ID, you can request a temporary
manufacturer ID by filling out a simp
3. In the Category property, select the general purpose or industry of the device. The
Category determines the device classes that will be available in Device Class
property. Alternatively, you can select one of the following options to determine and
organize the device classes shown in the Device Class property:
• ALL. Show all the existing device classes.
• Profiles By Name. Show an alphabetical list of all device classes with a profile.
• Profiles By Number. Show a numeric list (sorted by device class number) of all
device classes with a profile.
4. In the Device Class (CC:CC) property, select the primary function of the device. To
enter a device class value that has not yet been added to the standard list, select
boxes to the right (the calculator will convert the values to hex format).
5. In the Usage (UU) property, select the intended use of the device. The most
significant two bits are determined by the Has Changeable Interface and Use
Field Valued Defined By Functional Profile check boxes below the Usage
property.
If you are using a standard usage value, select the Use Field Defined By
Functional Profile check box below the Usage property, and select a standard
usage value from the list.
If the primary functional profile implemented by your device specifies custom usage
values, clear the Use Field Defined By Functional Profile check box below the
Usage property, select
decimal value from 0-255 in the box to the right (the calculator will convert the value
to hex format).
6. In the Channel Type (TT) property, select the channel type supported by the
device’s transceiver.
• If you are using an FT 5000 EVB or you are developing a device based on an FT
Smart Transceiver, select TP/FT-10.
• If you are using a PL 3150/PL 3170EVB or you are developing a device based on a
PL Smart Transceiver or PLT-22 transceiver, select PL-20C or PL-20N. The
PL-20C transceiver has the CENELEC EN 50065-1 standard protocol enabled,
the PL-20N transceiver does not.
• If you are using a transceiver that is not compatible with any of channel types in
the list, select Custom. To enter a channel type value that has not yet been
added to the standard list, select
decimal value from 0 to 255 in the box to the right (the calculator will convert
the value to hex format).
Note: Applications linking with the ISI libraries must select the program ID so
that it reports the channel type correctly. Non-interoperable device applications
should still use a standard program ID and advertise the channel type field
correctly.
7. In the Model Number (NN) property, enter the specific product model within the
range specified by the Min Model # and Max Model # properties in the Program
ID dialog. You can assign a unique model number for the specified manufacturer,