Connecting the mini fx/pl hardware – Echelon Mini FX User Manual
Page 46
Mini FX User's Guide
33
The NcMultiSensorExample application is pre-loaded on the FT 5000 EVBs and runs
in Interoperable Self-Installation (ISI) mode by default. You install and connect this
example application and the other examples using the LonMaker tool, or using the
ISI protocol. See the FT 5000 EVB Examples Guide for more information on using
these example applications.
For more information on the FT 5000 EVB, including how to use the I/O components,
service buttons, interfaces, and jumpers on the FT 5000 EVB hardware, see the FT 5000
EVB Hardware Guide.
Connecting the Mini FX/PL Hardware
To connect the Mini FX/PL hardware, follow these steps:
1. Unpack the equipment from the shipping carton. Avoid touching areas of integrated
circuitry, as static discharge could damage circuits.
2. Verify that all of the following hardware and software items listed in Table 2.2 are
present.
Table 2.2 Mini FX/PL Evaluation Kit Hardware and Software Items
Item Qty
PL 3150 EVB
1
PL 3170 EVB
1
Power supplies (90–240VAC 50/60Hz) with power cords
(US/Japan and Continental European) and integrated couplers
2
MiniGizmo 2
MiniGizmo Cables
2
U20 USB Network Interface
1
USB Extension Cable
1
Mini FX CD
1
LonScanner CD (Demo Edition)
1
3. Connect the PL 3150 and PL 3170 EVBs to the MiniGizmo I/O Boards using the
included MiniGizmo ribbon cables.
4. Connect the barrel connectors of two of the included power supplies into the barrel
jacks on the PL 3150 and PL 3170 EVBs, connect the power supplies to the included
power cords that are appropriate for you region (US/Japan or Continental European),
and then plug the power cords into a power outlet.
This connects the PL EVBs to the power line channel. The Mini FX/PL power
supplies include internal coupling to enable the evaluation boards to communicate
through the power supply. You cannot substitute another power supply for the Mini
kit power supplies, unless your alternative power supply provides equivalent
coupling.