Table a-3 zone 3 connector pin-out: j32 – ADLINK aTCA-N700 User Manual
Page 78
aTCA-N700 HW Users Guide
78
RTM_12V
O
RTM 12V from Front Blade
RTM_MP
O
RTM 3.3V from Front Blade
RTM_INSERT I
RTM Presence signal to IPMC (to GPIO)
1: No presence (3.3V)
0: RTM Inserted
RTM_ENABLE O
RTM Enable signal driven by IPMC (via GPIO). Implements
ENABLE# per AMC.0 Section 3.6.
0: Enable
1: Disable
RTM_SCL_B
O
IPMB-L from IPMC (to RTM MMC)
RTM_SDA_B
I/O
IPMB-L from IPMC (to RTM MMC)
IRQ_RTM_B I
Interrupt to LMP
0: Interrupt
1: Normal, no interrupt
RTM_RESET_B O
LMP reset signal to MMC for RTM payload reset
0: Reset
1: Normal
LMP_RTM_SCL
O
LMP I2C for RTM
LMP_RTM_SDA
I/O
LMP I2C for RTM
Table A-3 Zone 3 Connector Pin-out: J32
PIN
A
B
C
D
E
F
G
H
1 RTM_SFP_RX_P_0 RTM_SFP_RX_N_0 RTM_SFP_RX_P_1 RTM_SFP_RX_N_1 RTM_SFP_RX_P_2 RTM_SFP_RX_N_2 RTM_SFP_RX_P_3 RTM_SFP_RX_N_3
2 RTM_SFP_TX_P_0 RTM_SFP_TX_N_0 RTM_SFP_TX_P_1 RTM_SFP_TX_N_1 RTM_SFP_TX_P_2
RTM_SFP_TX_N_2 RTM_SFP_TX_P_3
RTM_SFP_TX_N_3
3 RTM_SFP_RX_P_4 RTM_SFP_RX_N_4 RTM_SFP_RX_P_5 RTM_SFP_RX_N_5
RTM_SFP_RX_P_6 RTM_SFP_RX_N_6 RTM_SFP_RX_P_7
RTM_SFP_RX_N_7
4 RTM_SFP_TX_P_4 RTM_SFP_TX_N_4 RTM_SFP_TX_P_5 RTM_SFP_TX_N_5 RTM_SFP_TX_P_6
RTM_SFP_TX_N_6 RTM_SFP_TX_P_7
RTM_SFP_TX_N_7
5 RTM_SFP_RX_P_8 RTM_SFP_RX_N_8 RTM_SFP_RX_P_9 RTM_SFP_RX_N_9 RTM_SFP_RX_P_10 RTM_SFP_RX_N_10 RTM_SFP_RX_P_11 RTM_SFP_RX_N_11
6 RTM_SFP_TX_P_8 RTM_SFP_TX_N_8 RTM_SFP_TX_P_9 RTM_SFP_TX_N_9 RTM_SFP_TX_P_10 RTM_SFP_TX_N_10 RTM_SFP_TX_P_11 RTM_SFP_TX_N_11
7 RTM_LED_CLK0_B RTM_LED_DATA0_B RTM_LED_CLK1_B RTM_LED_DATA1_B
8
9
BSC_SCL_B
BSC_SDA_B
10
Signal Name
I/O
Description
RTM_SFP_RX_P/N_[0:3]
I
SFP+ ports RX: Port 1~4
RTM_SFP_TX_P/N_[0:3]
O
SFP+ ports TX: Port 1~4
RTM_SFP_RX_P/N_[4:7]
I
SFP+ ports RX: Port 5~8
RTM_SFP_TX_P/N_[4:7]
O
SFP+ ports TX: Port 5~8
RTM_SFP_RX_P/N_[8:11]
I
SFP+ ports RX: Port 9~12
RTM_SFP_TX_P/N_[8:11]
O
SFP+ ports TX: Port 9~12
RTM_LED_CLK0/1_B
O
LED control CLK from Switch Fabric Device for the SFP+ ports
RTM_LED_DATA0/1_B
O
LED control DATA from Switch Fabric Device for the SFP+ ports
BSC_SCL_B
O
I2C connected to Switch Fabric Device
BSC_DATA_B I/O
I2C
connected
to Switch Fabric Device