Ethernet transceiver bcm5221, Cpld – ADLINK aTCA-N700 User Manual

Page 59

background image

aTCA-N700 HW Users Guide

59

0 : Off
1 : On

EMC_DB_1_GEB2_IO59PD
B5V0

K3 1V5_AVS_EN

O

1.5V,BCM AVS Enable

0 : Off
1 : On

EMC_DB_0_GEA2_IO59ND
B5V0

K2 1V2_EN

O

1.2V Enable

0 : On
1 : Off

GBB1_IO18PDB1V0 B20

IPMC_PWR_OK O

Power OK

0 : Off
1 : On

Reserved GPIO (To CPLD)
EMC_AB_9_IO08PDB0V0

D13

Connected to CPLD

I/O

FPGA_GPIO0

EMC_AB_7_IO07PDB0V0

A12

Connected to CPLD

I/O

FPGA_GPIO1

EMC_AB_2_IO05NDB0V0

B10

Connected to CPLD

I/O

FPGA_GPIO2

EMC_OEN1_N_IO03PDB0V
0

C10

Connected to CPLD

I/O

FPGA_GPIO3

GFA0_IO64NDB5V0

J6

Connected to CPLD

I/O

FGPA_GPIO4

GCC2_IO25PDB1V0

H18

Connected to CPLD

O

RTM Buffer Enable
0 : Enable
1 : Disable

EMC_AB_12_IO10NDB0V0 A14 PLD_TSALL

O

CPLD I/O Floating
0 : Normal

1 : Float

ADC_DAC
TM0 W8

CN6880_A

O

Thermal

monitor

GNDTM0 Y8

CN6880_A

O

Thermal

monitor

ADC0 Y9

VDD_2V5

I

Monitoring

Power

ADC1 AA8

VDD_3V3

I

Monitoring

Power

ADC2 V9

12V

I

Monitoring

Power

ADC3 AB8

NP_1V1_A

I

Monitoring

Power

TM2

AB1
2

CN6880_B O

Thermal

monitor

GNDTM1

AA1
2

CN6880_B O

Thermal

monitor

ADC4 U12

NP_1V1_B

I

Monitoring

Power

ADC5 V12

MSW_1V0

I

Monitoring

Power

ADC6 V11

MSW_AVS

I

Monitoring

Power

ADC7 T12

1V5_A

I

Monitoring

Power

ADC8 V14

1V5_B

I

Monitoring

Power

TM4 T13

P2041

O

Thermal

monitor

GNDTM2 U13

P2041 O

Thermal

monitor


9.3. Ethernet Transceiver BCM5221

The BCM5221 is a 10/100 BASE-T Ethernet transceiver that supports MII to MDI
interface conversion. The RMII side is connected to the IPMC and the MDI side is
connected to the base switch. This port is used for Serial-over-LAN (SOL). The IPMC
configures the device through the MDIO interface.

9.4. CPLD

The CPLD LCMXO640C-3FTN256C from Lattices plays important roles in collecting

and distributing many hardware signals among the IPMC, the CPU P2041 and many
other devices. The LMP configures the CPLD registers for the management. Refer to
the CPLD datasheet for details.