Carrier 38AH044-134 User Manual
Page 10
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Table ЗА — Units 38AH044-084 Physical Data — 50/60 Hz (English)
38AH
044
054
064
074
084
OPERATING WEIGHT WITH Cu-AI
REFRIGERANT (Approx) — Lb Cu-Cu
3259
3547
3309
3597
3565
3998
3812
4229
4057
4735
SHIP WEIGHT WITH COIL PROTECTION ONLY
(Approx) — Lb Cu-AI
Cu-Cu
3250
3538
3290
3578
3530
3963
3780
4197
4000
4678
TYPICAL OPERATING REFRIGERANT
Charge (Approx) — Lb
Qty of Circuits
Std
Opt
62
2
1
72
2
1
R-22
88
2
1
104
2
1
130
2
1
COMPRESSOR Type...Rpm
(Qty Cylinder) Compressor*
Model No. 06E
(Qty Cylinder) Compressor*
Model No. 06E
Oil Charge (Pt)
Capacity Control Stepsf
Reciprocating Semi-Hermetic
1750 @ 60 Hz; 1458 @ 50 Hz
Std
(4)A1
(4) B1
(4) A1
(6) B1
(6) A1
(6) B1
(6) A1
(6) B1
(6)A1
(6) B1
Std
250
250
250
265
265
275
275
299
299
299
Opt
(4)A1
(4) A2
(6) A1
(4) A2
(6) A1
(6) A2
(6) A1
(6) A2
(6)A1
(6) A2
Opt
250
250
265
250
275
265
299
275
299
299
Std
17
17
17
21
21
21
21
19
19
19
Opt
17
17
21
17
21
21
19
21
19
19
CONDENSER FANS (6 Blade) — 60 Hz
Qty...Dla (In.)
Ainlow (Cfm)
Speed (Rpm)
Total Power (kW)
4. .30
35,000
1140
6.2
52,000
6 .30
I
1140
93
51,000
CONDENSER FANS (6 Blade) -
Qty...Dia (in.)
Airflow (Cfm)
Speed (Rpm)
Total Power (kW)
■50 Hz
4. ,30
35,000
950
62
6 .30
52,000 I 51,000
950
93
CONDENSER COIL
Enhanced Co pper Tubes, Aluminum Lanced Fin
Rows...Fins per in.
2...17
2...17
3...17
2...19
3 .17
Face Area (sq ft)
80.5
80.5
80.5
116.7
1167
Storage Capacity (Lb per Circuit) at 120 F
35
35
55
55
80
CONNECTIONS
Suction, ODF (in.)**
2Va
Liquid, ODF (in.)**
%
Hot Gas Bypass, ODF (in.)
¥e
Table 3B — Units 38AH044-084 Physical Data — 50/60 Hz (SI)
38AH
044
054
064
074
084
OPERATING WEIGHT WITH
Cu-AI
1478
1501
1617
1729
1840
REFRIGERANT (Approx) — Kg
Cu-Cu
1609
1632
1813
1918
2148
SHIP WEIGHT WITH COIL PROTECTION ONLY
(Approx) — Kg
Cu-AI
1474
1492
1601
1715
1814
Cu-Cu
1605
1623
1798
1904
2122
TYPICAL OPERATING REFRIGERANT
R-22
CHARGE (Approx) — Kg
28 1
32 7
39 9
47 2
58 9
Qty of Circuits
Std
2
2
2
2
2
Opt
1
1
1
1
COMPRESSOR Type...R/s
Reciprocating Semi-Hermetic
29.2 @ 60 Hz; 24.3 @ 50 Hz
(Qty Cylinder) Compressor*
Std
(4) A1
(4)B1
(4) A1
(6) B1
(6) A1
(6) B1
(6) A1
(6) B1
(6) A1
(6) B1
Model No. 06E
Std
250
250
250
265
265
275
275
299
299
299
(Qty) Cylinder) Compressor*
Opt
(4)A1
(4) A2
(6) A1
(4) A2
(6) A1
(6) A2
(6)A1
(6) A2
(6)A1
(6) A2
Model No. 06E
Opt
250
250
265
250
275
265
299
275
299
299
Oil Charge (L)
Std
8 0
80
80
9 9
9 9
99
99
90
9.0
90
Opt
80
80
99
80
9.9
99
90
99
90
90
Capacity Control Stepsf
Z;
CONDENSER FANS (6 Blade) — 50 Hz
Qty...Dia (mm)
4.. 762
6
762
Airflow (L/s)
16 500
24 500
24 100
Speed (R/s)
15.8
15.8
Total Power (kW)
62
93
CONDENSER FANS (6 Blade) — 60 Hz
Qty...Dia (mm)
4.. 762
6. 762
Airflow (L/s)
16 500
24 500
24 100
Speed (R/s)
19.0
19.0
Total Power (kW)
62
93
CONDENSER COIL
Enhanced Copper Tubes, Aiuminum Lanced Fin
Rows...Fins per m
2.. 669
2.. 669
3,. 669
2 .. 782
3...669
Face Area (sq m)
7.48
7.48
7.48
10 84
10 84
Storage Capacity (Kg per Circuit) at 48.9 C
16
16
25
25
36
CONNECTIONS
Suction, ODF (in.)**
Liquid, ODF (in.)**
Hot Gas Bypass, ODF (in.)
2Va
Ve
%
LEGEND
Cu-AI
— Copper tubes with aluminum fins
Cu-Cu
— Copper tubes with copper fins
ODF
— Outside Diameter, Female
Opt
— Optional Single-Circuit Units
Std
— Standard Dual-Circuit Units
•Compressor A1 is lead on standard and optional single-circuit units
tCapacity control steps listed are for constant-volume units with no accesso
ries Refer to Table 19A or 19B, page 46, for additional system capacity
information
**For single-circuit units, suction ODF is 2% in. (66 7 mm) and liquid ODF is
IVs in (28.6 mm)
Single circuits have a factory-installed manifold; no
field modification is required.
NOTES:
1 Certified dimensional drawings available on request
2 Equivalent connection values in mm are as follows;
in.
mm
%
15.9
%
22 2
2Ув
54 0
10