5-34

Running the Array Configuration Utility

Writer: Rickard Project: Compaq Smart Array 3200 Controller Reference Guide Comments: 340862-002

File Name: F-CH05.DOC Last Saved On: 12/7/98 1:22 PM

COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED

Failed Drives or Interim Recovery Mode

If a drive fails and hardware fault tolerance is enabled, operation continues.
Replace the drive as soon as possible. Select a logical drive and press F3 to
monitor the status of drive recovery (Figure 5-26).

Figure 5-26. Rebuilding logical drive screen

Interim Recovery: The logical drive is operating, but a failed drive has
not been replaced. Replace drive as soon as possible.

Ready for Recovery: The logical drives are queued for recovery. This
status is displayed when another logical drive is already rebuilding or
expanding.

Rebuilding: The array is operating and rebuilding a replacement drive or
an online spare, if one was assigned.

Logical Drive Failed: If you have one or more logical drives that are not
protected by fault tolerance in an array, the data on these logical drives
will be lost. The Array Configuration Utility shows the logical drives as
FAILED. After drive replacement, any fault-tolerant logical drives
rebuild. The logical drives that were not protected (FAILED) become
available for data (the devices are reactivated automatically). If you have
a backup of the data, restore the data now.