POST Error Messages

continued

Code

Meaning

Recommended Action

1724

Slot x Drive Array - Physical Drive Position

Change(S) Detected - Logical drive

configuration has automatically been

updated.

This message indicates that logical drive

configuration has been updated automatically

following physical drive position changes. Press

F1 to resume.

1726

Slot x Drive Array - Array Accelerator Memory

Size Change Detected.

This message indicates that the array

accelerator configuration has been updated

automatically due to replacement of the Array

Accelerator (or controller) with one of them

having a different memory size. Press F1 to

resume.

1727

Slot x Drive Array - New Logical Drive(s)

Attachment Detected. If more than 32 logical

drives, this message will be followed by:

Auto-configuration failed: Too many logical

drives.

This message indicates that the controller has

detected an additional array of drives that was

attached when the power was off. The logical

drive configuration information has been

updated to add the new logical drives. The

maximum number of logical drives supported is

32-additional logical drives will not be added to

the configuration. Press F1 to resume.

continued