I-6 POST Error Messages

Writer: Rickard Project: Compaq Smart Array 3200 Controller Reference Guide Comments: 340862-002

File Name: P-APPI.DOC Last Saved On: 12/7/98 9:35 AM

COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED

POST Error Messages

continued

Code

Meaning

Recommended Action

1769

Slot x Drive Array - Drive(s) disabled due to

failure during expansion (possibly followed by

one of the following additional details:)

1. Array Accelerator Removed or Failed;

Expansion Progress Data Lost.

2. Expansion Progress Data Could Not Be

Read From Array Accelerator.

3. Expansion Aborted due to Unrecoverable

Drive Errors.

4. Expansion Aborted due to Array Accelerator

Errors.

Press F1 to continue with logical drives

disabled.

Press F2 to accept data loss and to re-enable

logical drives.

(RESUME = F1 OR F2 KEY)

Data has been lost while expanding the array,

the drives have been temporarily disabled.

Press F2 to acknowledge the data loss and re-

enable the logical drives. Restore data from

backup. If the Array Accelerator has failed,

replace the Array Accelerator board after the

capacity expansion progress has terminated.

never turn off the system and replace the Array

Accelerator board if capacity expansion is in

progress.

1774

Slot x Drive Array - Obsolete data found in

Array Accelerator. Data found in accelerator

was older than data found on drives. Obsolete

data has been discarded.

(RESUME = F1 KEY)

Data found in Array Accelerator is older than

data found on drives, due to drives having been

disconnected, used on another controller, and

then reconnected. Press F1 to discard older

data.

1775

Slot x Drive Array - ProLiant Storage System

Not Responding SCSI Port (y): Check storage

system power switch and cables. Turn the

system power off while checking the ProLiant

power and cable connections, then turn the

system power back on to retry.

(RESUME = F1 KEY)

Turn off power to system. Check external

ProLiant power switch. External drives must all

be powered-up before or at the same time as

the main system. Check cables. If retry does not

help, try replacing the cable, ProLiant firmware,

ProLiant backplane, or the Smart Array 3200

Controller.

continued