8. Use an LED light to ensure that the optical cavity is clean and free from dust or debris.

9. Ensure the desired OLPF module is clean and free of debris.
10. Insert the OLPF module.
11. Replace and loosely tighten the four (4) M2x0.4 x 4 mm OLPF module screws (P/N 600-0224) in a cross

pattern (“X” pattern) using a T6 Torx driver. DO NOT FULLY TIGHTEN.

12. Fully tighten the four (4) OLPF module screws in a cross pattern (“X” pattern) using a T6 Torx driver. DO

NOT exceed 30 in-oz, or damage may occur.
WARNING: DO NOT OVERTIGHTEN.

13. Replace the lens mount.

Ensure optical cavity

is clean and free of

debris

Replace the OLPF

module and screws