CREATE LENS CALIBRATION FILES
The calibration process creates a calibration file for the current focal length of the electronic lens. Calibrate the
lens at each available focal length to create a full lens calibration file.
1. Attach a DSMC Canon Mount or DSMC Nikon Mount to the BRAIN.
2. Attach an electronic lens.
3. Manually set the first focal length you want to calibrate.
4. There are two (2) ways to start the lens calibration process:
‒ When you attach a lens that the camera does not recognize, the “Unsupported Lens Found” dialog box
displays and asks if you want to calibrate the lens. Select Create Custom Lens Config.
‒ Go to Menu > Settings > Maintenance > Calibrate > Lens and select Create....