Sensor sync, Red dsmc operation guide – RED DSMC User Manual
Page 154

COPYRIGHT © 2015 RED.COM, INC
RED DSMC OPERATION GUIDE
955-0020_V5.3, REV-J | 154
SENSOR SYNC
Sensor Sync is achieved when a genlock signal is provided that is compatible with the current monitor output
frequency, project time base, and sensor frame rate. While operating in Sensor Sync, sensor timing is locked
to the genlock signal.
Sensor Sync requires the following synchronized settings:
SETTING
MENU LOCATION PATH
Genlock signal frequency
N/A; external genlock device
HD-SDI monitor output frequency
Menu > Settings > Display > Monitor Control
Project Time Base
Menu > Settings > Project > Frame Rate
Sensor Frame Rate
Menu > Settings > Project > Frame Rate
NOTE: HDRx is not available when Genlock Sensor Sync is enabled.
To set up and enable Sensor Sync Mode, follow the instructions below:
1. Connect the desired genlock device to the BRAIN using a 3BNC-to-00 LEMO Sync Cable.
A. Connect the green BNC connector to the genlock device.
B. Connect the 00B LEMO connector to the SYNC port on the BRAIN.
2. Go to Menu > Settings > Setup > GPIO/Sync.
3. On the Sync tab, set Sensor Sync Mode to Genlock.
4. Set Genlock Source to Brain.
5. Go to Menu > Settings > Display > Monitor Control.
6. On the Monitor tab, select Brain HDSDI from the drop-down menu.
7. Select the desired monitor output frequency from the Frequency drop-down menu.
NOTE: Select Auto to automatically match the HD-SDI output to the current project time base.
The GEN indicator in the Lower Status Row turns green when a compatible genlock signal is present and
genlock is enabled. The SYNC indicator in the Lower Status Row turns green when Sensor Sync is achieved.
Timecode and Genlock
enabled