Downloader programming, System version menu – Interlogix Concord 4 REV J Installation Manual User Manual
Page 99
Chapter 3: Programming
Concord 4 Installation Manual
93
Light X to Sensor Y
Shortcut: 08n where n
is light number minus 1
Default: 0
This menu attaches light x to sensor y. Each time a selected sensor is
tripped, the selected light will turn on and a 5-minute timer will start. The
sensor must be learned into the current partition before it can be
attached.
To attach a light to a sensor:
1. With the display showing
LIGHT 1 TO SENSOR y
(current
setting), press A
or B
to select the light number.
2. Enter the sensor number (01 to 96). The display flashes the entered
setting. Press #
and the display shows the new setting.
3. Repeat the process until all desired lights are attached to sensors.
To detach a light from a sensor:
1. With the display showing
LIGHT 1 TO SENSOR y
(current
setting), press A
or B
to select the light number.
2. Enter 0
as the sensor number and press #.
System version menu
The System version menu lets you view and identify panel hardware and
software. This information is primarily used for troubleshooting purposes.
System version
Shortcut:
010 (factory code),
011 (system number),
012 (system level),
013 (software version)
This menu lets you view and identify panel hardware and software
version.
To view and identify the system version:
1. Press A
or B
until the display shows
SYSTEM VERSION
.
2. Press #
and the display shows
FACTORY CODE nnn*nnnn
.
3. Press B
and the display shows
SYSTEM NUMBER *nnnnnnn
.
4. Press B
again and the display shows
SYSTEM LEVEL nnnn
.
5. Press B
again and the display shows
SW VERSION nnnnx
(panel firmware version).
Downloader programming
The panel can be programmed remotely using Enterprise Downloader. Use the
information you recorded in Appendix A
“System planning sheets” on page 117
to inform the downloading operator of the programming requirements for this
system.