Chapter 2: Installation

Concord 4 Installation Manual

31

Backup battery

Use the 60-681 (12 VDC, 4.5 or 5 Ah) or 60-680 (12 VDC, 7Ah) backup battery.
The battery is automatically tested every 24 hours. Without AC power, the panel
will shut down if the battery voltage falls below 10.2 VDC. Replace the battery
when necessary with the same battery model.

Note:

The backup battery leads must be routed along the side of the enclosure

and secured with a cable tie.

Figure 26: Connecting panel power transformer and backup battery

Black (negative)

Red (positive)

Battery

1

2

16.5 VAC

Power up

To power up the panel:

1. Connect the red and black backup battery leads (included with panel) to the

lugs on the panel.

2. Connect the other ends of the backup battery leads to the battery terminals.

3. Plug the transformer into an outlet that is not controlled by a switch.

4. Alphanumeric touchpads display ************, then SCANNING BUS DEVICES,

and finally a date and time display.

Note:

If alphanumeric touchpads

don’t display anything, immediately unplug

the transformer and disconnect the backup battery.

5. To permanently mount the transformer, unplug it and remove the existing

screw securing the AC outlet cover

WARNING:

Use extreme caution when securing the transformer to a metal

outlet cover. You could receive a serious shock if a metal outlet cover drops