Appendix B: Reference tables
Concord 4 Installation Manual
143
Response characteristics
Table 30 below describes the response characteristics.
Table 30: Response characteristics
Response characteristics
Description
Momentary trip time
The point remains active for nn seconds (n is 1 to 12 seconds).
The default is 4 seconds.
3-minute trip time
The point remains active for 3 minutes.
Siren-time trip time
The point remains active while the sirens are sounding.
Sustained trip time
The point remains active for the duration of the event.
Siren pattern
The point activates and deactivates according to the current
alarm type:
Auxiliary: fast on/off/on
Police: constant on
Fire: repeating
Trip delay
The point activates 30 seconds after the trigger event occurs.
Response numbers
Table 31 below describes the response numbers.
Table 31: Response numbers
Response number
Siren tracking
Trip delay
Response time
00
No
No
Momentary
01
No
No
3 minutes [5]
02
No
No
Siren time [2]
03
No
No
Sustained [3]
04
No
Yes [4]
Momentary
05
No
Yes [4]
3 minutes [5]
06
No
Yes [4]
Siren time [2]
07
No
Yes [4]
Sustained [3]
08
Yes [1]
No
Momentary
09
Yes [1]
No
3 minutes [5]
10
Yes [1]
No
Siren time [2]