beautypg.com

Zones/sensors – Interlogix Concord 4 REV J Installation Manual User Manual

Page 103

background image

Chapter 4: Testing and troubleshooting

Concord 4 Installation Manual

97

Command

System response

* (STATUS)

Indicates current system status

7, 1

Turns chime feature on and off

7, 2

Turns energy saver on and off

7, 4

Partition jump without entering code (only if partition
security option is off)

7, 6

Identifies alarms in memory

7, 7, n (n = output number [1to6])
1 to 2 = onboard outputs;
3 to 6 = module outputs

Turns the output on or off. (This command is only
functional after output text is entered into panel
memory.)

8, code, 2

Initiates a phone test

8, code, 3

Initiates a sensor test

8, installer code, 3

Initiates a dealer sensor test

8, code, 6

Partition jump

8, code, 8

View event history

0, 0

Turns all controlled lights on and off

0, n (n = light number 1 to 9)

Turns individual controlled light on and off

Zones/sensors

Test sensors/zones after all programming is completed; whenever there is a
change in environment, equipment, or programming; and whenever a zone- or
sensor-related problem occurs.

If the system does not respond as described in the following procedure, see
Troubleshooting.

Note:

While the sensor test is a valuable installation and service tool, it only tests

sensor operation for the current conditions. You should perform a sensor test
after any change in environment, equipment, or programming.

To test zones/sensors:

1. Place all sensors and zones in their nonalarm state.

2. At an alphanumeric touchpad, enter the sensor test mode by pressing 8,

installer code, 3. The touchpad sounds one beep and displays SENSOR
TEST. The panel starts a 15-minute timer.

3. Trip each zone/sensor one at a time. Touchpads (and interior sirens) should

sound one short, high-pitched beep, and the display should show the sensor
name (or number) and OK.