Chapter 3: Programming

70

Concord 4 Installation Manual

Table 12 below describes how to trip different types of sensors to program (learn)
them in the panel.

Table 12: Tripping sensors

Sensor

How to trip the sensor

Hardwired zones

Start with the zone in its “normal” state, and then trip the zone into its
alarm state. A normally closed door, for example, should be closed
when you begin the learn sensors process. To trip the zone, open the
door.

Wireless sensors

Follow the instructions included with each sensor.

Wireless door/window
sensors with external
contacts

Place the external contact in the alarm condition, and then activate the
sensor tamper switch.

Handheld wireless
touchpads

Press the Bypass button.

Keyfobs

Press and hold the Lock and Unlock buttons together until the keyfob
LED flashes.

ELM keyfobs

Press and release the Unlock button twice quickly, then press and hold
until the LED flashes three times.

Press and release the Unlock button once quickly, then press and hold
until the LED flashes two times.

Press and hold the Unlock button until the LED flashes once.