Appendix B: Reference tables
Concord 4 Installation Manual
131
#
Name
Application
Alarm
Delay
R
e
s
to
ra
l
S
u
p
e
rv
is
o
ry
C
S
R
e
p
o
rt
C
h
im
e
(L
e
v
e
l)
A
c
ti
v
e
l
e
v
e
ls
12 Entry/
exit delay
Driveway gates and
entrances that require a
twice extended delay time.
Police
Twice
extende
d
2,3
13 Instant
perimeter
Exterior doors and
windows
Police
Instant
2, 3
14 Instant
interior
Interior doors (Hardwired)
Police
Follower
2,3
15 Instant
interior
Interior PIR motion
sensors. (RF wireless)
Police
Follower
2,3
16 Instant
interior
Interior doors. (Hardwired)
Police
Follower
3
17 Instant
interior
PIR motion sensors (RF
wireless.)
Police
Follower
3
18 Instant
interior
Instant interior cross-
zone# PIR motion
sensors. *
Police
Follower
3
19 Delayed
interior
Interior doors that initiate a
delay before going into
alarm.
Police
Interior
3
20 Delayed
interior
PIR motion sensors that
initiate a delay before
going into alarm.
Police
Standar
d
3
21 Local
instant
interior
24-hour local alarm zone
protecting anything that
opens and closes.
Police
Instant
1,2,3
22 Local
delayed
interior
Same as group 21, plus
activation initiates a delay
before going into alarm.
Police
Standar
d
1,2,3
23 Local
instant
auxiliary
24-hour local alarm zone
protecting anything that
opens and closes.
Auxiliar
y
Instant
1,2,3
24 Local
instant
auxiliary
24-hour local alarm zone
protecting anything that
opens and closes. Sirens
shut off at restoral.
Auxiliar
y
Instant
1,2,3
25 Local
special
chime
Notify the user when a
door is opened. Sounds
emit from a local
annunciator.
Special
chime
Instant
1,2,3