Chapter 1: Introduction

2

Concord 4 Installation Manual

Planning the installation

This section describes system capabilities to help you get familiar with the
system. Appendix A

“System planning sheets” on page 117 provides planning

sheets that let you record the hardware and programming configuration of the
system. Fill in all necessary information ahead of time to help prepare for system
installation.

Standard panel

Table 1 below shows the standard panel capabilities.

Table 1: Panel capabilities

Capabilities

Concord Express v4

Concord 4/Concord Commercial
v4

Zones

32

96

Partitions

2

6

Bus devices

16

16

User codes

16

230

Table 2 describes the basic panel (out-of-box) hardware capabilities for all
panels.

Table 2: Basic panel hardware capabilities

Power

Input for an AC step-down, plug-in style transformer.

Auxiliary power output

Output that supplies 9 to 14 VDC with up to 1 amp for bus devices
and hardwired detectors, such as smoke and motion detectors.

Bus A and B

Input and output that provides communication between bus devices
and the panel.

Siren driver

Output that can drive an 8-ohm load and provides intrusion and fire
alarm sounds for partition 1 (15 watts maximum).

Two onboard outputs

Can be used to activate other signaling devices based on system
events.
Out 1 is a 9 to 14 VDC source output, limited to 1.0 amp max.
Out 2 is an open-collector output, rated up to 14 VDC, 300 mA max

Microphone input

Input used for 2-way audio when used in conjunction with the
Interrogator 200 audio verification module.

Eight supervised hardwired
zones

Inputs for various hardwired detectors. Zone 8 can be set up in
programming to accept two-wire smoke detectors. It sources 9 to 14
VDC, 90mA max.