beautypg.com

System event triggers – Interlogix Concord 4 REV J Installation Manual User Manual

Page 142

background image

Appendix B: Reference tables

136

Concord 4 Installation Manual

System event triggers

Table 26 below describes the system event triggers.

Table 26: System event trigger

System event

Description

Trigger
number

Null trigger (used for direct control) Activates only by schedule or direct command. 000

Fire alarm

When fire sirens are started.

001

Police alarm

When police sirens are started.

002

Auxiliary alarm

When auxiliary sirens are started.

003

Any audible alarm

When any of the above sirens are started.

004

Silent alarm (sensor groups 2, 3,
and duress)

When a group 2 or 3 sensor goes into alarm or
when a duress alarm is activated (does not
include groups 25, 27, 28, or 32).

005

Any audible or silent alarm

When any alarm is started (does not include
groups 25, 27, 28, or 32).

006

HOM group 27, 28, 32 in alarm

When a sensor in group 27, 28, or 32 goes
into alarm.

007

Major trouble (phone or receiver
failure)

When a receiver failure (S94) or a phone
failure (S96) occurs.

008

Arming to stay or away

When the system is armed to level 2 or 3.

009

Arming to away

When the system is armed to level 3.

010

AVM is interactive (audio session
in progress)

When the central station operator begins
listening or talking to the premises.

011

Fail-to-

communicate (panel can’t

call CS or pager)

When the fail-to-communicate output is
activated.

012

AVM trip (edge)

When an AVM alarm occurs, output is
activated momentarily.

013

Keychain touchpad star button-
press

When the star button on a keychain touchpad
is pressed.

014

Smoke power (for resetting four-
wire smoke detectors)

Deactivated when hardwire smoke detectors
need to be reset.

015

Exterior siren

Activated for police or fire alarms.

016

Interior siren

Activation follows all system noises

017

AVM trip (pulse)

When an AVM alarm occurs, output is
deactivated for 10 ms

018

State of system status

Follows the state of system status (ready or
trouble).

019

Tamper condition

When any tamper is tripped

020