Interlogix Concord 4 REV J Installation Manual User Manual
Page 45

Chapter 3: Programming
Concord 4 Installation Manual
39
Partition 1 copy
Default = None
After programming all settings pertaining to partition 1, you may make an
exact copy to use for partitions 2 to 6. This helps reduce programming
time when the system is set up for multiple partitions. If there are certain
settings that are unique to partitions 2 to 6, simply advance to the
appropriate menu and make the necessary changes.
To copy partition 1:
1. With the display showing
PARTITION 1 COPY,
press #, installer
code, #. The display flashes.
2. Press #. The display shows
DONE
.
Clear memory
Clearing memory deletes all existing programming information (except the
dealer code).
Note:
Clearing the memory erases onboard hardwired zone factory
programming.
To clear panel memory:
1. With the system in program mode, press A
or B
until the display shows
CLEAR MEMORY.
2. Press #. The display shows
ENTER CODE TO CLEAR
MEMORY.
3. Enter the four-digit installer or dealer code (if programmed) and press #.
After about 5 seconds, the system restarts and the panel scans the bus to
learn all bus devices. If the system doesn’t respond as shown, repeat the
process.
Exiting
programming
After all installer/dealer programming is completed, exit programming
mode.
To exit programming mode:
1. Press *
until the display shows
SYSTEM PROGRAMMING.
2. Press A
or B
until the display shows
EXIT PROGRAMMING
READY.
3. Press #. The touchpad displays the time and date
.