Chapter 3: Programming

Concord 4 Installation Manual

79

Onboard options - output programming settings

Output 1, 2

Shortcuts:
11100 (output 1ptn)
11101 (configuration);
11110 (output 2 ptn),
11111 (configuration)

Default:
Ptn 1, 01614 (output 1)
Ptn 1, 01710 (output 2)

This setting assigns the partition and the five-digit configuration number
for the two onboard outputs. The configuration number determines:

• Which system event activates the selected output.
• The duration or time the output is activated.

The first three digits represent the trigger number of an event (such as
triggering an alarm, opening a sensor, or arming the system). The last
two digits represent how the output responds, For example, momentary
switching, maintained (or latched) switching, or switching for a preset
time.

Note:

If you want to configure an output for user output control you must

use the output text feature to name the output. If no output text is
programmed, user output control will not function for that output.

Use the system event trigger and response numbers listed in Table 31
on page 143.

To set up onboard output 1 and 2 partition and configuration
assignments:

1. With the display showing

ONBOARD OPTIONS,

press #, B. The

display shows

OUTPUT PROGRAMMING

.

2. Press #

and the display shows

OUTPUT 1

. Press B

to select output

2.

3. Press #

and the display shows

PARTITION ASSIGN n

(current

setting).

4. Press 1 to 6 to assign the output to the desired partition, then press #.
The display shows

PARTITION ASSIGN

(new setting).

5. Press B

and the display shows

CONFIGURATION tttrr

(current setting).

6. Enter the configuration number. The display flashes the entered
number. Press #

and the display shows the new setting.

7. Press #

and repeat the process until all outputs are programmed.