Chapter 3: Programming

74

Concord 4 Installation Manual

Device ID

Default: None

This menu lets you change the bus device ID number when replacing a
defective bus device.

To change a device ID:

1. With the display showing the desired bus device, press #, #. The
display shows

DEVICE ID

(current ID).

2. Enter the ID of the new bus device. The display flashes the entered
selection. Press #

and the display shows the new setting.

3. Exit programming mode.

4. Remove AC and battery power from the panel.

5. Replace the defective bus device with a new one.

6. Apply AC and battery power to the panel.

Partition assign

This menu lets you assign bus devices to work in the desired partition.

Note:

SuperBus 2000 8Z input modules, SuperBus 2000 4-relay output

modules, and SuperBus 2000 RF receivers are not assigned to
partitions.

To assign bus devices to partitions:

1. With the display showing the desired bus device, press #.

2. Press A

or B

until the display shows

DEVICE PTN

and then press

#. The display shows

PARTITION ASSIGN n.

3. Press 1

to 6

to select the desired partition. The display flashes the

entered selection. Press #

and the display shows the new setting.