Chapter 2: Installation

Concord 4 Installation Manual

19

Figure 10: Connecting hardwired interior speakers

SPKR SPKR

SPKR SPKR

Not used

Not used

7

8

7

8

Exterior/interior piezo sirens

Onboard output 1 (OUT 1

—terminal 9) is a 9 to 14 VDC switched, programmable

output that can handle a maximum of 1,000 mA current. The default setting
(01614) activates the output 30 seconds after a police or fire alarm condition
occurs. This allows you to connect a piezo siren without changing the output
configuration number in programming. This output is typically used for exterior
siren applications. Connect multiple piezo sirens in parallel. (For more
information on output configuration numbers, see “Onboard options menu” on
page 78.)

Note:

For 24-hour backup, external power drain is limited to 90 mA (during

normal standby condition), using a 4.5 or 5.0 Ah battery, or 190 mA continuous
using a 7.0 Ah battery.

Piezo dynamic exterior siren (13-950)

Connect the siren to panel as shown in Figure 11 on page 20.