Chapter 2: Installation

18

Concord 4 Installation Manual

Speakers and sirens

The panel provides one siren driver output for intrusion (steady), fire (temporal
3), and auxiliary (on-off-on-off) alarm sounds. This output trips only for partition 1
alarms. Install all sirens/speakers indoors in a concealed location.

Note:

Do not connect a bell or piezo siren to the speaker output (terminals 7 and

8).

The output can drive a single 8-ohm speaker or a multiple speaker circuit of 8
ohms or higher. When connecting two or more speakers, wire them in series.
Wiring speakers in parallel can permanently damage the panel. Compatible
speakers are shown below.

Caution:

To avoid disabling the panel speaker output, do not make speaker

connections with the panel power on.

15-watt speaker (13-060)

For exterior siren applications, connect the speaker to the panel using 18-gauge
wire as shown in Figure 9 below.

Figure 9: Connecting exterior speakers

Panel terminals

SPKR SPKR

SPKR SPKR

Splice

Two 8-ohm speakers
in series (16 ohms)

Hardwired interior speaker (60-528)

Connect interior speakers to the panel (see Figure 10 on page 19) using 18-
gauge wire.

Caution:

Connect only the large speaker to panel terminals 7 and 8 as shown.

The smaller speaker cannot handle output to terminals 7 and 8. To avoid
damaging the speaker, do not connect the smaller speaker to terminals 7 and 8.