System exclusive message, Oabout model 10, Oabout device id – Roland VS-890 User Manual
Page 96: Identity reply, Midi muhine control commands, Midi machine control responses, Odata request (rq1), Midi implementation, Start, Continue
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
MIDI Implementation
•start
Status
FAH
•Continue
Status
FBH
•Stop
Status
FCH
■System Exclusive Message
Status
FOH
Byte
FOH
UH
ееН
F7H
Data Bytes
Status
HH.ddH,...,eeH
F7H
Description
Status of Exclusive Message
Manufacture ID
41H Roland's Manufacture ID
7EH Universal Non Realtime Message
7FH Universal Realtime Message
Data: OOH - 7FH (0-127)
Data
EOX (End of Exclusive Message)
The VS-890 can transfer and receive the internal parameters information using exclusive
messages, and also can be controlled by the external devices using exclusive messages.
The VS-890 can transmit and receive Universal System Exclusive messag«, Data
Request(RQl) and Data sct(D51)as the System Exclusive message.
OAbout Model 10
The Model ID of the VS-890 is00H,2FH as for Data Request (RQl)and Data set(DTl).
The VS-890 also can transfer and receive 00НД4Н to be compatible with the V5-880EX.
The model ID of Data Request (RQl) and Data set (DTI) transferred from the VS-890 is
according to the value of SYSTEM parameter "MlD;ModelID.“
The VS-890 can receive both model ID's.
OAbout Device ID
Exclusive messages are not assigned to any particular MIDI channel.
Instead, thev have their own s|ieciat control parameter called device ID.
The Roland exclusive messages use device IDs to specify various devices.
The VS-890 sends exclusive messages using the device ID ООН - IFH, and receives the
exclusive miKsages which device ID is same as its device ID or 7FH.
The value of the device ID is the value set on the SYSTEM parameter "MIDiDevicelD” minus
one.
•Universal System Exclusive Message
OINQUIRY MESSAGE
Identity Request
Status
Data Bvtes Status
FOH
7EH,Dev,06H,01H F7H
Bxlfi
Description
FOH
Status of Exclusive Message
7EH
Universal System Exclusive Message Non Realtime Header
Dev
Device ID (or7FH)
06H
Genera! Information (sub ID 91)
OlH
Identify Request (sub ID 92)
F7H
EOX (End of Exclusive Message)
The message is used to request the particular information of the VS-890.
The V5-S*X) does not transmit the message.
If the VS-890 received the message and the device ID of the message is same as its device ID
or 7FH, the VS-890 transmits the following Identity Reply message.
Identity Reply
Status
FOH
Byte
FOH
7EH
Dev
06H
02H
41H
mmH mmH
ООН ООН
ООН
ООН
ssH ssH
F7H
Data Bytes
SlOiU£
7EH,Dev,06H,02H,41H,mmH,mmH,
RH
OOH,OOH,OOH,OOH.ssH,ssH
Description
Status of Exclusive Message
Universal System
Exclusive
Message
Non
Realtime
Header
Device ID
General Information (sub ID 91)
Identify Request (sub ID 92)
Manufacture ID (Roland)
Device Family Code (V5-8W/ VS-880EX)
Device Family No.
Softw'are Revision Level
EOX (End of Exclusive Message)
The value of Ihe device family code is according to the value of SYSTEM parameter
•'MIDrModeUD."
If "MIDiModellD” is "890,’’ The value of the device family code is 2FH.01H.
If "MID:ModeIID" is ''88EX,'’The value of Ihe device family code is 14H,01H.
MIDI Muhine Control Commands
Status
FOH
Bvie
FOH
7FH
Dev
06H
aaH
bbH
F7H
Daia_Byles
Status
7FI I,Dev,06H,aaH,.... bbH
F7H
Description
Status of Exclusive Message
Universal Syslrni Exclusive Message Realtime I leader
Device ID (or 7FH>
MMC Command Message
Command
Command
EOX (End of Exclusive Message)
see
“3.
MIDI Machine Control" section
MIDI Machine Control Responses
Status
FOH
Bvte
FOH
7FH
Dev'
07H
aaH
bbH
F7H
Г)
Data Bytes
Status
7FH.Dev,07H,aaH,..., bbH F7H
Description
Status of Exclusive Message
Universal
System
Exclusive
Message
Realtime
Header
Device ID
MMC Response Message
Response
Response
EOX (End of Exclusive Message)
see "3. MIDI Machine Control" section
•Data Transfer (RQl, DT1)
OData Request (RQ1)
Status
FOH
Data Bytes
4iaDev,mmH.mmH,11H,
aaH,bbH,ccH,55H,ssH,S5H,Sum
Status
F7H
96