Algorithm List
Parameter (full name)
Setting
Function
LNK (Link);
Link (Link Switch)
Channel B follows the settings for Channel A.
On, Off
Specifies if Channel B follows or does not follow the
settings for Channel A.
MCA, MCB(Mic Converter):Converts the characteristics of the low-end general-purpose microphone into
the characteristics of the high-end microphone for studio appiication.
MicConv (Switch)
On, Off
Turns the microphone converter on or off.
Input (Input)
See the column on
the previous page.
Sets the microphone type used for recording.
Out (Output)
See the column on
the previous page.
Sets the microphone types to be simulated.
Phase (Phase)
Normal, Invers
Sets the microphone phase.
BCA, BCB (Bass Cut Filter): Cuts off undesired low frequency band sounds such as pop noise.
BassCut (Switch)
On, Off
Turns the bass cut filter on or off.
Freq (Frequency)
Thru, 20 - 2000 Hz
Sets the frequency for cutting off undesired low frequency
band sounds such as pop noise.
DSA, DSB (Distance): Simulates the frequency characteristics and time difference due to distance
difference.
Distance (Switch)
On, Off
Turns the distance on or off.
Prox.Fx (Proximity Effect)
-12-+12
Corrects the low frequency band characteristics due to the
distance from the sound source.
Time (Time)
0-3000 cm
Simulates the time difference due to the distance from the
sound source.
LMA, LMB (Limiter): Prevents distortion by suppressing signais at high levais.
Limiter (Switch)
On, Off
Turns the limiter on or off.
Thrsh (Threshold)
-60-0 dB
Sets the volume level to start suppressing excessive input.
Attack (Attack Time)
0-100
Sets the time from when the input level exceeds the
threshold level to when the effect begins to apply.
Release (Release Time)
0-100
Sets the time from when the input level drops below the
threshold level to when the effect ceases to apply.
Freq (Defect HPF Frequency)
Thru, 20 - 2000 Hz
Normally, sets “Thru".
Sets the cutoff frequency of the level detection section.
Output Level (Output Level)
-60- +24 dB
Sets the volume of the compressor sound.