48. If the oxygen
level is not within the specified range, adjust the level using the ▲ and ▼
arrow keys. This will adjust the output voltage to the blower motor as indicated on the
display. Pressing the ▲ arrow key increases the oxygen level and pressing the ▼ arrow key
decreases the oxygen level.
49. Once the oxygen level is within the specified range at 30%, press the ENTER key to store
the selected blower output voltage for the 30% valve position.
50.
Press the ▲ arrow key until SET Valve Position appears on the C-MORE display.
51. Press the CHANGE key. SET Valve Position will begin to flash.
52.
Press the ▼ arrow key until the SET Valve Position reads 16%, then press the ENTER key.
53.
Press the ▼ arrow key until CAL Voltage 18% is displayed.
54. Press the CHANGE key. CAL Voltage 18% will begin to flash.
55. The oxygen level at the 18% valve position should be as shown below. Also, ensure that the
carbon monoxide (CO) and nitrogen oxide (NOx) readings do not exceed the values shown.
Table 4-6: Combustion Oxygen Levels for a
18% Air/Fuel Valve Position
Oxygen %
± 0.2
Carbon Monoxide
NOx
8.0 %
<50 ppm
<30 ppm
56.
If the oxygen level is not within the specified range, adjust the level using the ▲ and ▼
arrow keys. This will adjust the output voltage to the blower motor as indicated on the
display. Pressing the ▲ arrow key increases the oxygen level and pressing the ▼ arrow key
decreases the oxygen level.
57. Once the oxygen level is within the specified range at 16%, press the ENTER key to store
the selected blower output voltage for the 16% valve position.
58. This completes the Natural Gas Combustion Calibration procedure.