3 sensor log, Gf-123, Benchmark 2.0ln low nox boiler – AERCO BMK 2.0 LN Natural Gas (SN G-11-1861 and above) User Manual

Page 115

background image

GF-123

Benchmark 2.0LN Low NOx Boiler

Chapter 9

OMM-0046_0E

I

nstallation, Operation and Maintenance Manual

RS232 Comm.

PR1 08/20/12

AERCO International Inc.● 100 Oritani Dr. ● Blauvelt, NY 10913. ● Ph: 800-526-0288

Page 115 of 170

means that no more than 30 minutes of data can be lost if the unit loses power. Table 9-2
shows a sample Operation Time Log for a boiler:

The Operation Time Log can only be accessed through the RS232 interface using a laptop or
other terminal device. Ten operation time records are displayed for each T command entry. The
operation time log can be cleared ONLY by factory authorized personnel using the Clear Log
option in the Factory menu.

NOTE

The Sensor (S) Log can store up to 1200 records. Therefore, to view the
most recently logged record, enter “S” followed by 0 (zero) and then press
Enter (i.e. S0 ). To view earlier records in reverse chronological
order, enter S and press Enter. To go back 200 or 700 records, enter S200
or S700, etc. and press Enter.

9.4.3 Sensor Log

The sensor values can be logged at a different rate if needed by setting the Sensor Log Interval
in the Diagnostics Menu. The log interval can vary from once every minute to once every day.
Table 9-3 shows a sample Sensor Log every 5 minutes for a boiler running in Constant Setpoint
mode.

Table 9-1. Sample Fault Log Display

No.

Fault Message

Cycle

Date

Time

0

Direct Drive Signal Fault

609 1/10/02

8:42am

1

Low Gas Pressure

366 7/04/01

5:29pm

2

Loss of Power

0 1/01/01

11:50am

Table 9-2. Sample Operation Time Log Display

Status

Fire Rate

Flame

Run Length

Date

Time

Off, Direct Drive

0

0

8

1/15/02

2:35pm

Run, Direct Drive

38

100

34

1/15/02

2:27pm

Run, Direct Drive

31

100

30

1/15/02

1:53am

Run, Direct Drive

35

100

2

1/15/02

1:23pm

Run, Direct Drive

29

100

0

1/15/02

1:21pm

Ignition

0

0

0

1/15/02

1:20pm

Off, Switch

0

0

35

1/15/02

12:30pm

Run, Manual

40

100

0

1/15/02

11:55am

Ignition

0

0

0

1/15/02

11:55am

Power-up

0

0

0

1/15/02

11:50am

Table 9-3. Sample Sensor Log Display

Setpt

Outlet

Outdr

FFWD

Aux

Inlet

Exhst

CO

O2

Flow

Date

Time

130

181

OPEN

OPEN

OPEN

OPEN

OPEN

0

.0

0

1/15/02 5:51pm

130

180

OPEN

OPEN

OPEN

OPEN

OPEN

0

.0

0

1/15/02 5:46pm

130

180

OPEN

OPEN

OPEN

OPEN

OPEN

0

.0

0

1/15/02 5:41pm

130

179

OPEN

OPEN

OPEN

OPEN

OPEN

0

.0

0

1/15/02 5:36pm

130

180

OPEN

OPEN

OPEN

OPEN

OPEN

0

.0

0

1/15/02 5:31pm

130

180

OPEN

OPEN

OPEN

OPEN

OPEN

0

.0

0

1/15/02 5:26pm

130

180

OPEN

OPEN

OPEN

OPEN

OPEN

0

.0

0

1/15/02 5:21pm

130

180

OPEN

OPEN

OPEN

OPEN

OPEN

0

.0

0

1/15/02 5:16pm

130

179

OPEN

OPEN

OPEN

OPEN

OPEN

0

.0

0

1/15/02 5:11pm

130

180

OPEN

OPEN

OPEN

OPEN

OPEN

0

.0

0

1/15/02 5:06pm