4.3 Command Communication
57
Setting Trigger Input (Starting Test Mode)
To set characters of the trigger on/Off command, send the following command.
Example 1: Change the trigger on command to S.
Function
Command being sent
Respons
e
Description
Error
Code
Setting signal type
Change
WP05n
OK
n= 0: Level
1: One-shot
00, 02
05, 07
14
Confirm
RP05
05n
Setting one-shot input time
Change
WP42nnn
OK
nnn=001 to 225
(by 100 ms step)
Confirm
RP42
42nnn
Setting time constant of trig-
ger input
Change
WP04n
OK
n= 0: 2 ms
1: 10 ms
Confirm
RP04
04n
Setting state of trigger input
Change
WP03n
OK
n= 0: Normal-open
1: Normal-close
Confirm
RP03
03n
Starting test mode when trig-
ger input turns on.
(To specify the test mode, use
the command below.)
Change
WP06n
OK
n= 0: Disable
1: Enable
Confirm
RP06
06n
Specifying the test mode to be
started when trigger input
turns on.
Change
TRGTn
OK
N= 1: Reading rate check mode
2: Tact check mode
00, 02
05, 08
14
Confirm
TRGT
TRGTn
Starting test mode when
power is turned on.
Change
TESTn
OK
n= 0: Reset
1: Reading rate check mode
2: Tact check mode
Confirm
TEST
TESTn
Setting characters of trigger
on command
Change
WP56hhh...
OK
hhh...=Trigger on command (Up to 8 characters)
* Specify characters in HEX (hexadecimal) code.
00, 02
05, 11
14
Confirm
RP56
56hhh...
Setting characters of trigger
off command
Change
WP57hhh...
OK
hhh...=Trigger off command (Up to 8 characters)
* Specify characters in HEX (hexadecimal) code.
Confirm
RP57
57hhh...
Note
WP5653CR
S
S=53h