10 communication setting, 11 communication strings setup, 3 setup software operating procedure – KEYENCE BL-180 User Manual
Page 46

3.3 Setup Software Operating Procedure
38
3.3.10
Communication setting
1. Place the mouse cursor at the item to be changed and click it, or move to the
target item by pressing [TAB]. Then, change the setting using [Space].
2. When setting the header string, delimeter, and read error, click [Communica-
tion strings] or press [ENTER] to move to the communication strings setting
screen.
3. Click the Return button or press [ENTER] to return to the main setting
screen.
(Communication) protocol --> Page 47
The setup software does not allow you to set the baud rate to 19200 to 38400 bit/
s. If you want to set the baud rate within this range, use the serial commands (see
page 58).
3.3.11
Communication strings setup
1. Place the mouse cursor at the item to be changed and click it, or move to the
target item by pressing [TAB]. Then, change the setting using [Space].
2. Select appropriate values for Header string and Delimiter from among the
displayed items. When you select Custom, the following appears:
Then, you can enter the desired value from the keyboard (within 5 charac-
ters).
Note